3. You will hear "Press one to change."
timer's dry contacts to pins 21 and 22. When the switch is closed the
tom right when the Time-of-Day input is active.
Using the VM500-5
2. You will hear the programmed PIN number
Programming a PIN Number
ture. The alarm override input is a dry-contact type. The VM500-5
4. You will hear "Press one to change"
7. You will hear the PIN number you just entered
The Alarm Override Input
The PIN number must be 4 digits and must not include a # sign.
7. Enter the number, followed by a #
3. You will hear the programmed number
The VM500-5 uses a 4-digit PIN number (0000-9999) to identify you
sources 12v at 12ma dc. To prevent the VM500-5 from calling out dur-
9
9. You will be automatically returned to the Program Menu
5. You will hear "Enter number"
2. If this is the first time setup, go to step 6
1. From the Program Menu, press 8 to change the PIN number
8. You will be automatically returned to the Program Menu
pin number)
6. You will hear "Enter number, then press pound"
5. Press 1 if you wish to make a change or press any other
4. Press 1 if you wish to make a change or press any other but-
bottom LED will light, and the VM500-5 will not call out.
6. Enter a four digit number (do not put a # anywhere in your
8. You will hear the number you just entered.
when calling the device or during callout procedures. After program-
Friday, June 27, 2003 15:26
The alarm override input is used to disable the emergency call out fea-
1. From the Program Menu, press 5 for the local ID
ing a defrost cycle, or a predetermined period of time, the user can wire a
page 9
button to return to the Program Menu
On models equipped with the display, the display show a "*" on the bot-
vm505.pub
ton to return to the Program Menu
ming the PIN number write it down here. _____________
<< < [Pag.9] > >>
Esta version es la html del arhivo pdf vm505, genearada por domotica.name desde www.temperatureguard.com
Archivos relacionados:AN505E ANDCP-E DCP_Getting_ DCP_IP_Setup DCP_Manual_v DCP_manual IP_Setup_rev MA41201 MA412_Wiring MOLLY303_Wir MOLLY305_Wir NetworkAddre VM500-5_Inst VM500_INSTAL VM500_Mounti VM5032-2002 VM50522 VM505E_510Em VM52002 VaccineRepor ab305v aci-1k-2w-bp aci-1k-2w-sp computer_roo ma401_wiring ma403 molly303_spe pump_sequenc rl-b_wiring_ vm500-5E-DCP vm500-6wirin vm501_manual vm501_specsh vm502_specsh vm504_manual vm50518 vm50520 vm5057r14 vm506_manual vm50811 vm508_specsh vm509 vm51001 vm510_specsh vm511_specsh vm54001 vm540lv_wiri actuadores activethermal airwaysystem automatedceilingregisters coolcomponents easywarmfloor heatizon numinus pcslighting relampit taiserver temperatureguard touchplate warmzone