Rev 1; 6-25-07
Mute
the Master or Salve Mute Input will only mute the zones on that Controller. (If 12VDC is applied to the
1. Using a 2-male to 1-female 3.5mm mono mini plug Y adapter, plug the two male ends into the Mute
Inputs on the C-4.4 Master and Slave Controllers.
19
2. Plug a 3.5mm mini plug wire into the female end of the Y adapter and terminate as appropriate for the
Figure 13 Mute Trigger In Parallel Connection
device triggering audio mute. Maintain proper polarity.
voltage for audio mute can be connected to the Mute Inputs on both controllers in parallel to mute all
The Audio Mute Inputs on the Master and Slave Controllers are independent in that a 12VDC trigger to
zones when 12VDC is present as shown in Figure 13.
Master, only zones 1-4 will mute. If voltage is applied to the Slave only Zones 5-8 will mute.) The trigger
background image
C-4.4 Installation Instructions
<< < [Pag.19] > >>

Esta version es la html del arhivo pdf C-4-4InstallationInstruct, genearada por domotica.name desde www.nexusaudiosystems.com

Archivos relacionados:C-4-1Install C6OwnersManu CEDIAExhibit NexusBrochur NexusC4-4Bro NexusC4_1Bro NexusC4_4Bro NexusT-2Broc T2Installati ZED-2Manual seguridad cctvsafe extremecctv freezealarm goodbarsecurity highpowersecurity icontrol infosecinstitute intamac jacksonsystems keepsafer mraccess napcosecurity nexusaudiosystems securityandmore securitymaninc smartvue techno-mall tripplite vigitron vikingelectronics wilife