pool wall and leave until silicone cures.
fiberglass before threading nuts onto the threaded rods.
pool through the holes that are drilled in the pool wall.
pool wall to ensure that the seal is watertight.
to Figure 4.10. To help prevent cross threading, thoroughly clean the exposed thread of any excess
hole in the pool wall. It should penetrate at least a 1/2" into the pool wall when permanently installed.
and conduit (with possible adapters) in place. Even if a bond beam is not being poured for the pool, it is
· Feed the pool side ends of the threaded rods and bonding lug screw through the holes drilled in
manently installed, 1-1/4" to 1-1/2" of threaded rod will penetrate beyond the pool wall surface. Refer
hydraulic hose from the Fastlane Swim Unit to the junction box is 3/8" and the run hose from the junction box
to the Power Unit is 1/2". The junction box must be located at the elevation equal to or higher than the pool deck.
the bonded rebar grid. If no rebar is being used, be sure to bond the threaded rod to other metallic pool
If the hydraulic hose runs are greater than 25', in order to reduce pressure loss and potential reduction in
· Apply the provided silicone adhesive to the side of the PVC bracket plate that will mate against the
· Once installed, the adapter threaded into the 3/8" PVC bracket plate should be seen from inside the
The wall mount bracket must be attached on the pool wall as explained in the installation instructions in
under the deck and carry two (2) hydraulic hoses.
If the hydraulic hose runs back to the Power Unit are less than 25', it is not necessary to step up to 1/2" run
Section 4. Attached to this bracket are two (2) lengths of 1" poly pipe or 1-1/2" PVC flex pipe that run back
Fig. 4.10
Section 5
essential for the operation of the Fastlane that this assembly be securely anchored in concrete. Refer to
1.25" TO 1.5" INTO POOL
hose to reduce pressure loss. Instead, the 3/8" hydraulic hose can run directly to the Power Unit in the protec-
Figure 4.10. Only when the concrete has cured is it okay to remove the washers and jam nuts and install
speed, a junction box must be used. It is at the junction box where a step up to 1/2" run hose occurs. The
· Attach the bonding lug to the rear of the pool, and thread the screw for the bonding lug through the
the fiberglass pool wall, and using the provided washers and jam nuts, secure the rod tightly to the
items and pool equipment. Attach a bonding wire to the bonding lug on the back of the bracket, and be
Fastlane® Swim Unit Installation
background image
· Thread the 3/8" threaded rod into the holes in the bracket, so that once the PVC bracket plate is per-
8
sure to bond the threaded rod to the pool's bonding grid.
JUNCTION BOX AND 1/2" RUN HOSES (OPTIONAL)
Once the bracket is securely attached to the rear of the pool wall, tie the bent pieces of threaded rod into
Pour the concrete collar around the top flange of the pool, securely encasing the threaded rod assemblies
THREAD ROD EXTENDS
PACK BACKSIDE OF POOL WALL
tive conduit.
WITH CONCRETE
the Fastlane. Note: Do not throw away these washers and nuts, because they will again be used to
anchor the Fastlane to the pool wall.
<< < [Pag.9] > >>

Esta version es la html del arhivo pdf wallmountOM, genearada por domotica.name desde www.endlesspools.com

Archivos relacionados:ARSC Assemblyinst EPSSOpGuidev FAQ FLPoolOMDMve FLPoolOMWMWQ FLPoolOMWMWQ FL_Brochure FOP012309 FastlaneOMv4 FastlanePool FastlaneWarr Fastlane_Pla IntroBook PDFConfigsAG PDFConfigsFI PDFConfigsFI PDFConfigsPI PDFConfigsPI Permit_Consi SwimSpaBroch SwimSpaPlann USBRENDLESSP coastallivin eheater epiwarranty finishchoice gheater howtoswim options planningguid motores activateddecor aquaair-wetdry auton avrak closystems endlesspools hpproducts.net innovativepools mediadecor peerlessmounts plasma-tv-lift silentgliss-usa somfysystems watercop