the quick disconnect.
or lower floor level than the Power Unit, it is preferable to
Down from vacuum inlet
mounting plate. Extend tubing up through top plate to trunk line.
·
For under-floor trunk line glue vacuum tubing (PA046) into elbow and
·
(PA092) into each other then into short 90degree elbow on the
run the tubing up to a high point above the inlet and down
18/2 or 20/2 low voltage control wire.
1" ­ 2" to 10'
the vacuum tubing with tie straps. Splice wires at Vacuum Tee or
·
·
to the Power Unit.
stud, preferably at same height as the electrical plugs.
·
·
·
before the tee.
If the lines are run "plumb" without a drop down before each tee or a
Rough-into
Assemble the Water Outlet by gluing quick disconnect to the back of
the loop free to move.
·
1-1/2" before each tee to stop the water from running back
Where impossible or impractical to drop the line down
Up from
disconnect and secure water line to vacuum tubing or stud leaving
up for trunk lines under the floor and down for overhead trunk lines.
trap (speed bump) has been installed in the lines.
water when the following situations exist:
7
Glue (using PVC glue) a Short 90degree elbow (PA089) to the
or at a slope down to the unit. Drop the trunk line down
·
Connect the water line to the fitting on the back of the quick
overhead trunk line.
The trunk line should be firmly supported absolutely plumb
Vacuum Inlet - Use 2" O.D. PVC Vacuum Tubing and Fittings.
"high point"
Vertical Branch lines must reach a "high point"
·
vacuum inlet
Water Outlet
run absolutely plumb or
home run each line.
before each tee, a trap ("speed bump") may be installed
on slope down
extend through floor plate to trunk line.
the mounting plate. Note: direct the elbow on the quick disconnect
For overhead trunk line glue (2) 90degree sweep spigot elbows
When it is impossible or impractical to run the line to a high point and
vertical line and enter the trunk line from above or on a
up the line. When a vacuum inlet is installed on the same
under-floor trunk line
overfilling the P-trap at the inlet valve.
Splice wires at Vacuum Tee or home run each line.
Nail or screw mounting plate (PA131 or for 2"x3" walls PA132) to
The tubing system is routed either up to an attic or
2/18 or 2/20 low voltage control wire.
immediately above or as close as possible to the
8
Attach to the vacuum tubing with tie straps.
Run wire through upper opening on the mounting plate and attach to
·
slope. This is to avoid "drain-back" from the trunk line
·
mounting plate (elbow pointing down).
Note: Care should be taken that the system is regularly rinsed with
then down to the Power Unit
background image
In-Wall Vacuum Inlets and Water Outlets
Connect to Power Unit
Installation of the Vacuum Tubing
This allows for the tubing to be looped to allow for later servicing of
Rough-in to
pipe chase, or down to the lower level or basement.